Showing posts with label ip door readers. Show all posts
Showing posts with label ip door readers. Show all posts

Monday, April 29, 2013

Authentication in Door Access Control Systems


Door Access Control Systems have been around for many years. Recently new technology has increased security by providing better authentication of the person at the door.  Before selecting your system, you should first determine the degree of security you need.  For example, the security level for an office building could be different from a secure military facility.  There is a tradeoff between cost, ease of use and security level provided.   Key-locks were the original method of controlling the door.  It has been around for thousands of years.  The key provided the authentication.  Since a key can be lost or stolen it is not as secure as using more sophisticated biometric authentication system.  Here is a review of the most common methods for authentication and the level of security they provide.

Keypads
Keypads are probably the least expensive, but also provide the lowest protection.  A PIN number can be forgotten or someone can see the key number entry.  There are two types of keypad systems, one that is included with the lock (sometimes referred to as keyless entry) and another type that includes a separate keypad and electric lock. 
The simple mechanical lock with keypad is primarily designed for home use but can also be used in a small business.  The problem with this system is that it doesn’t have the ability to contain unique numbers so it is difficult to control when there are many people using it.  If someone leaves the organization you have to change the number that everyone else uses. 

The separate keypad is used to control an electric lock on the door.  It is usually used with a central control box that stores an individual code for each person registered in the system.  This system can be used to control access on multiple doors, but it must be used correctly to assure security.  I have seen situations where organizations have issued the same number for everyone.  This type of situation provides very little security.   The database allows you to register each person, and assign the rules about when and where they can enter.  This is more secure but still has problems with stolen numbers and people having to remember the number. 

Card Access Systems
Instead of having each person remember a PIN number, you can provide cards that contain unique codes.  The early readers used bar code, magnetic strip or even Wiegand effect type technology.  
Today most card systems use some type of radio frequency connection and are more secure.  The cards have become credentials that include keyfobs and lanyard style cards and the number is encrypted.   

The latest door access control readers are attached to the network and use standard IP protocols just like computers on the network.  These IP door readers can handle a number of different types of credentials.  The latest “smart cards” not only include unique encrypted numbers but can contain information about the person who holds the credential.  Smart cards such as Mifare type credentials have been used in Europe to pay for transportation.  The credential has built in storage that holds the cash to be used for payment.    

Using credentials is a lot more secure than using a keypad, but there are some concerns about people losing their card or even of higher technology theft of identity using special electronic techniques. 

Security can be increased by adding IP camera systems.  This allows real time and recorded video to be monitored.  

Biometric Authentication
The latest method for authentication is to use a person’s key biometric factors such as fingerprints, voice identification and facial recognition.  This is probably the most secure form of authentication. 

Fingerprint identification:  This has been around for a number of years.  It has become more reliable and less expensive.  You may be familiar with fingerprint identification used by police to catch criminals.  This started out as a manual process but is now automated.  It uses specific characteristics of the fingerprint such as arch, loop and whorl patterns to recognize one print from another.  The same type of identifier is also used in automated access control systems.  Each person is registered in the system using their fingerprints.  The database in the access control system uses the results of the recognition circuits to create a unique pattern for each person.   This pattern can then be compared every time a person uses the system to enter the door. 


There are a number of technologies used to read the fingerprint such as optical, ultrasonic and capacitive.  Each method has pros and cons associated with it.  This system is very secure but there can be problems with reliability.  Dirt and scratches on a finger can deny entry.  

Facial Recognition:  These systems provide an easy way to authenticate a person.  They have gotten much better over the last few years, but there are still some issues with reliability.  For example, if a person comes to the door wearing dark glasses, the system may not be able to recognize them. 

To increase reliability some facial recognition systems have added other biometrics such as Body motion and voice recognition to improve performance.  FST21 Corporation is an example of a multi-modal biometric system that views people as they approach the door.  This provides a much faster analysis and allows people to move quickly through the doorways.  

 It is a challenge for all of us to select the best equipment at the best price.  With that in mind, we continue to review the latest technology from companies all over the world in order to increase our safety and security.   

Please contact us if you need help with your access control systems.  You can contact us at 914-944-3425 or use our contact form.

Friday, January 27, 2012

Door Access Control Review

Door access control systems have been around for many years. The early units used centralized control panels with simple card readers at the doors. To install these systems the readers were wired to a controller and then back to a central control panel. They also required power to be wired to each of the locks usually from a separate control panel.

Over the years more intelligent devices were developed, and now most of the intelligence is located at the reader near the door. The latest IP door readers make use of the Ethernet PoE network and are very easy to install. This article reviews the pros and cons of both systems and compares the cost of installation.

We have used a 6 reader system as an example. Let’s start with the cost comparison. First we looked at the older centralized system with control panel. I’m leaving out the cost for door locks, sensors and Rex buttons because it’s the same in both cases.



Centralized System

Equipment Cost
Cost for the Equipment consists of the readers and the central box with power supply.
Each door requires a door controller and a prox card reader.
6 - Door controllers = $510 x 6 = $3060
6 - Prox readers = 194 x 6 = $1164

The central control box and power supply is required:
1- Site Controller $568
1- Software $768 (This can be a lot higher depending on company)
1- Power supply $495
Total $1831

Grand Total for equipment and software - $ 10,985

Wiring

Traditional 18-2 or composite wiring from the panel to the reader can range from $0.90 to $1.30 per foot. Assuming the 6 readers average 50 feet from the panel at minimum wiring cost will be $270


Installation
Installation is a variable because it depends on the prep work for mounting panel enclosure, distance from the central box, the type of walls and ceilings, and other physical considerations in the building. It goes without saying that multi-building installation adds to the complexity. We used the labor costs at one installation which required about 5 days at about $1000 per day = $5000

Total cost for the system is $16,255.00

IP Reader System
The new all-in-one Isonas door access reader-controller connects right to the network and doesn’t use a central control box. The credential database is entered into a computer running Crystal Matrix software. All this information is downloaded to each of the readers so even if the network goes down, the reader can still control entry.




Equipment cost
Door access control reader-controller $700 x 6 = $4200
Software is free unless you need web based control = $500
8 port network switch with PoE support = $200
Total equipment is $4900

Wiring

Cat 5/6 wiring from the network switch to the reader-controller is about 0.30 per foot. Assuming the 6 doors average 50 feet from the network switch the wiring cost will be $90.00


Installation
Labor cost is again somewhat variable but since there are fewer devices to configure and install at the door physical installation is simplified. As for electrical work, since wiring of the reader-controller to the door strike is contained at the door and PoE supplies power to the lock, we have cut out the need for wiring back to one central point. Thus labor costs are much less. Typically an install requires ½ the time and resources to install so 3 days at $1000 per day is $3000 for labor.

The total system cost is then $7,990.

Summary

Classic System
The classic system has been around for many years so there are many experienced licensed electricians available

IP Reader System
Since the new IP systems use computer networks, a new breed of installers with network and computer expertise is required. The good news is that this can be an in-house self-installation for many organizations that have an IT staff. They have been running the network wire to computers so they have no problem connecting to the same RJ45 connections that are used by computers. The only things they may need help with are installation of the electric locks. In this case they can bring in locksmiths who are familiar with these types of locks. The locksmith installs the electric lock and wires to the pigtail of the reader.

Integration with other systems
Since the IP access control uses the network it's very easy to integrate into an IP camera system. By connecting Intercoms to the IP camera, a remote person can manually release the door. The audio connections go through the camera and find their way back to the safety station that's running Video Management Software. When the call button is pushed on the intercom the safety station is notified by an alarm sound, and the safety officer can see and talk to the person at the door. They can then unlock the door by pushing a button on their computer screen.





Deployment across a Campus
IP systems have another major advantage. They can be deployed anywhere you have a network connection, so if you have multiple buildings connected over a LAN or WAN the IP system can make use of this network and easily communicate to the central control software on a computer in one of the buildings.



Conclusion
Network attached IP door access systems are very easy to install and have excellent flexibility. They can be located across the campus or across the city as long as you have a network connection.

If you need help defining your door access control system, please contact us at 1-800-431-1658 (in the USA) or + 914-944-3425 or use our contact form.